• Home
  • 제품(PRODUCT)
    • Fossil Power Generation >
      • Gas Turbines
      • Steam Turbines
      • Generators
      • Power Plants
    • Power transmission
    • Low Voltage >
      • Advanced Preventavice Fire Protection
    • Medium Voltage
    • Smart Grid >
      • Over Current Protection Relay >
        • SIPROTEC 4 7SJ64
        • SIPROTEC 4 7SJ62
        • SIPROTEC 7SJ602
        • SIPROTEC 7SJ600
        • SIPOTEC 7SJ46 easy
        • SIPROTEC 7SJ45 easy
      • Generator Protection Relay >
        • SIPROTEC 4 7UM61/62
      • TR Protection Relay >
        • SIPROTEC 4 7UT613/633/635 Differential Protection Relay
        • SIPROTEC 4 7UT 612
      • LINE Protection Relay >
        • SIPROTEC 4 7SA6
        • SIPROTEC 4 7SA522
        • SIPROTEC 7SD52/53
        • SIPROTEC 4 7SD61
      • BUS Protection Relay >
        • 7VH60(1CT Input)
        • 7SS60 (2 Measuring Input)
        • 7SS522 (Central Unit)
      • Various Protection Applications >
        • Motor protection - 7SK80
        • V, F, Protection - 7RW600
        • Breaker Management Relay - 7VK61
      • SIPROTEC 5
      • DIGSI 4 S/W
      • Application for RTD-Box TR1200
      • SIMEAS P - Power Meter
      • SIEMENS R - PMU
    • SCADA System SIMATIC Wincc
  • 카다로그
    • SIPROTEC 4 7SJ64
    • SIPROTEC 4 7SJ62
    • SIPROTEC 7SJ602
    • SIPROTEC 7SJ600
    • SIPROTEC 7SJ46 EASY
    • SIPROTEC 7SJ45 EASY
    • SIPROTEC 4 7UM61/62
    • SIPROTEC 4 7UT613/633/635 Differential Protection Relay
    • SIPROTEC 4 7UT612
    • SIPROTEC 4 7SA6
    • SIPROTEC 4 7SA522
    • SIPROTEC 7SD52/53
    • SIPROTEC 4 7SD61
    • SIPROTEC 7VH60
    • SIPROTEC 7SS60
    • SIPROTEC 7SS522
    • SIPROTEC 7SK80
    • SIPROTEC 7RW600
    • SIPROTEC 7VK61
    • SIPROTEC 5 7KE85
  • NEWS
  • 보호계전기 이론
    • 디지털 보호계전기 개요
    • 디지털 보호계전기 구조
    • 보호계전기 관련 용어
    • 디지털 보호계전기 기능
    • 보호계전기란?
    • 변성기&변류기란 ?
    • CT 및 PT결선
    • SBO 기능
    • 보호계전기의 역사
    • 전력계통보호방식
    • DIGSI 4 S/W 사용법
    • DIGSI4 통신 및 Display Editor
    • 디지털 보호계전 시스템 동향
  • Contact Us
    • Our Partner
  • 교육훈련

SIPROTEC 4 7VK61 - Breaker Management Relay

Picture
Description

The SIPROTEC 4 breaker management relay 7VK61 is a highly flexible autoreclosure, synchro-check and circuitbreaker failure protection unit. This unit is used for the single and threepole auto-reclosure of a circuit-breaker, after this circuit-breaker has tripped due to a fault. The synchro-check function ensures that the two circuits being reconnected by closing the circuit-breaker are within a defined safe operating state before the CLOSE command is issued.
The 7VK61 is also applicable as circuitbreaker failure protection. A breaker failure occurs when the circuit-breaker fails
to correctly open and clear the fault after single or three-pole trip commands have been issued by the protection. It is then
necessary to trip the relevant busbar zone (section) to ensure fault clearance. Together with the above-mentioned protection
functions, the following additional functions of the 7VK61 can be applied: end-fault protection, pole-discrepancy
protection, overvoltage protection and undervoltage protection. As a member of the numerical SIPROTEC 4 relay family,
it also provides control and monitoring functions and therefore supports the user with regard to a cost-effective power system
management.
______________________________
Protection functions
• Single and/or three-pole auto-reclosure
• Synchro-check with live/dead line/bus measurement
• Closing under asynchronous conditions (consideration of CB operating time)
• Circuit-breaker failure protection with two stages (single and three-pole with/without current)
• End-fault protection
• Pole-discrepancy protection
• Overvoltage/undervoltage protection
Control function
• Commands f. ctrl. of CB and isolators Monitoring functions
• Operational measured values
• Self-supervision of the relay
• Event buffer and fault protocols
• Oscillographic fault recording
• Monitoring of CB auxiliary contacts
• Switching statistics
Features
• All functions can be used separately
• Initiation/start by phase-segregated or
3-pole trip commands
• Auto-reclosure for max. 8 reclose cycles
• Evolving/sequential trip recognition
• Auto-reclosure with ADT, DLC, RDT
• Synchro-check with ΔV, Δϕ , Δf measurement
• Breaker failure protection with highly secure 2-out-of-4 current check detectors
• Breaker failure protection with short reset time and negligible overshoot time
CommunicatIon interfaces
• Front interface for connecting a PC
• System interface for connecting to a
control system via various protocols
– IEC 61850 Ethernet
– IEC 60870-5-103 protocol
– PROFIBUS-FMS/-DP
– DNP 3.0
• Rear-side service/modem interface
• Time synchronization via
– IRIG-B or DCF77 or system interface