• Home
  • 제품(PRODUCT)
    • Fossil Power Generation >
      • Gas Turbines
      • Steam Turbines
      • Generators
      • Power Plants
    • Power transmission
    • Low Voltage >
      • Advanced Preventavice Fire Protection
    • Medium Voltage
    • Smart Grid >
      • Over Current Protection Relay >
        • SIPROTEC 4 7SJ64
        • SIPROTEC 4 7SJ62
        • SIPROTEC 7SJ602
        • SIPROTEC 7SJ600
        • SIPOTEC 7SJ46 easy
        • SIPROTEC 7SJ45 easy
      • Generator Protection Relay >
        • SIPROTEC 4 7UM61/62
      • TR Protection Relay >
        • SIPROTEC 4 7UT613/633/635 Differential Protection Relay
        • SIPROTEC 4 7UT 612
      • LINE Protection Relay >
        • SIPROTEC 4 7SA6
        • SIPROTEC 4 7SA522
        • SIPROTEC 7SD52/53
        • SIPROTEC 4 7SD61
      • BUS Protection Relay >
        • 7VH60(1CT Input)
        • 7SS60 (2 Measuring Input)
        • 7SS522 (Central Unit)
      • Various Protection Applications >
        • Motor protection - 7SK80
        • V, F, Protection - 7RW600
        • Breaker Management Relay - 7VK61
      • SIPROTEC 5
      • DIGSI 4 S/W
      • Application for RTD-Box TR1200
      • SIMEAS P - Power Meter
      • SIEMENS R - PMU
    • SCADA System SIMATIC Wincc
  • 카다로그
    • SIPROTEC 4 7SJ64
    • SIPROTEC 4 7SJ62
    • SIPROTEC 7SJ602
    • SIPROTEC 7SJ600
    • SIPROTEC 7SJ46 EASY
    • SIPROTEC 7SJ45 EASY
    • SIPROTEC 4 7UM61/62
    • SIPROTEC 4 7UT613/633/635 Differential Protection Relay
    • SIPROTEC 4 7UT612
    • SIPROTEC 4 7SA6
    • SIPROTEC 4 7SA522
    • SIPROTEC 7SD52/53
    • SIPROTEC 4 7SD61
    • SIPROTEC 7VH60
    • SIPROTEC 7SS60
    • SIPROTEC 7SS522
    • SIPROTEC 7SK80
    • SIPROTEC 7RW600
    • SIPROTEC 7VK61
    • SIPROTEC 5 7KE85
  • NEWS
  • 보호계전기 이론
    • 디지털 보호계전기 개요
    • 디지털 보호계전기 구조
    • 보호계전기 관련 용어
    • 디지털 보호계전기 기능
    • 보호계전기란?
    • 변성기&변류기란 ?
    • CT 및 PT결선
    • SBO 기능
    • 보호계전기의 역사
    • 전력계통보호방식
    • DIGSI 4 S/W 사용법
    • DIGSI4 통신 및 Display Editor
    • 디지털 보호계전 시스템 동향
  • Contact Us
    • Our Partner
  • 교육훈련
Picture
Differential Protection Relay for Two Line Ends
Protection functions
• Differential protection for universal use with power lines and cables on all voltage levels with phase-segregated measurement (87L)
• Two line ends capability
• Suitable for transformers in protected zones (87T)
• Restricted earth-fault protection (87N) if a transformer iswithin the protection zone
• Well-suited for serial compensated lines
• Two independent differential stages: one stage for sensitive measuring for highresistance faults and one stage for highcurrent
faults and fast fault clearance
• Breaker-failure protection (50BF)
• Phase and earth overcurrent protection with directional element (50, 50N, 51, 51N, 67, 67N)
• Phase-selective intertripping (85)
• Overload protection (49)
• Over/undervoltage protection (59/27)
• Over/underfrequency protection (81O/U)
• Auto-reclosure single/three-pole (79)

Control functions
• Command and inputs for ctrl. of CB and disconnectors (isolators)

Monitoring functions
• Self-supervision of the relay
• Trip circuit supervision (74TC)
• 8 oscillographic fault records
• CT-secondary current supervision
• Event logging / fault logging
• Switching statistics

Front design
• User-friendly local operation
• PC front port for convenient relay setting
• Function keys and 8 LEDs f. local alarm

Communication interfaces
• 1 serial protection data (R2R) interface
• Front interface for PC connection
• System interface
− IEC 61850 Ethernet
− IEC 60870-5-103 protocol
− PROFIBUS-DP, DNP 3.0 and MODBUS
• Service / modem interface (rear)
• Time synchronization via IRIG-B, DCF77 or system interface

Features
• Browser-based commissioning tool
• Direct connection to digital communi

CATALOG
MANUAL
Powered by Create your own unique website with customizable templates.