• Home
  • 제품(PRODUCT)
    • Fossil Power Generation >
      • Gas Turbines
      • Steam Turbines
      • Generators
      • Power Plants
    • Power transmission
    • Low Voltage >
      • Advanced Preventavice Fire Protection
    • Medium Voltage
    • Smart Grid >
      • Over Current Protection Relay >
        • SIPROTEC 4 7SJ64
        • SIPROTEC 4 7SJ62
        • SIPROTEC 7SJ602
        • SIPROTEC 7SJ600
        • SIPOTEC 7SJ46 easy
        • SIPROTEC 7SJ45 easy
      • Generator Protection Relay >
        • SIPROTEC 4 7UM61/62
      • TR Protection Relay >
        • SIPROTEC 4 7UT613/633/635 Differential Protection Relay
        • SIPROTEC 4 7UT 612
      • LINE Protection Relay >
        • SIPROTEC 4 7SA6
        • SIPROTEC 4 7SA522
        • SIPROTEC 7SD52/53
        • SIPROTEC 4 7SD61
      • BUS Protection Relay >
        • 7VH60(1CT Input)
        • 7SS60 (2 Measuring Input)
        • 7SS522 (Central Unit)
      • Various Protection Applications >
        • Motor protection - 7SK80
        • V, F, Protection - 7RW600
        • Breaker Management Relay - 7VK61
      • SIPROTEC 5
      • DIGSI 4 S/W
      • Application for RTD-Box TR1200
      • SIMEAS P - Power Meter
      • SIEMENS R - PMU
    • SCADA System SIMATIC Wincc
  • 카다로그
    • SIPROTEC 4 7SJ64
    • SIPROTEC 4 7SJ62
    • SIPROTEC 7SJ602
    • SIPROTEC 7SJ600
    • SIPROTEC 7SJ46 EASY
    • SIPROTEC 7SJ45 EASY
    • SIPROTEC 4 7UM61/62
    • SIPROTEC 4 7UT613/633/635 Differential Protection Relay
    • SIPROTEC 4 7UT612
    • SIPROTEC 4 7SA6
    • SIPROTEC 4 7SA522
    • SIPROTEC 7SD52/53
    • SIPROTEC 4 7SD61
    • SIPROTEC 7VH60
    • SIPROTEC 7SS60
    • SIPROTEC 7SS522
    • SIPROTEC 7SK80
    • SIPROTEC 7RW600
    • SIPROTEC 7VK61
    • SIPROTEC 5 7KE85
  • NEWS
  • 보호계전기 이론
    • 디지털 보호계전기 개요
    • 디지털 보호계전기 구조
    • 보호계전기 관련 용어
    • 디지털 보호계전기 기능
    • 보호계전기란?
    • 변성기&변류기란 ?
    • CT 및 PT결선
    • SBO 기능
    • 보호계전기의 역사
    • 전력계통보호방식
    • DIGSI 4 S/W 사용법
    • DIGSI4 통신 및 Display Editor
    • 디지털 보호계전 시스템 동향
  • Contact Us
    • Our Partner
  • 교육훈련

SIPROTEC Compact 7SK80 Motor Protection Relay with Local Control

Picture
The SIPROTEC Compact 7SK80 is a multifunctional motor protection relay. It is
designed for asynchronous induction type motors of all sizes. The relays have
all the functionality to be applied as a backup relay to a transformer differential
relay. The SIPROTEC Compact 7SK80 offers highest reliability at major functionality
by the synergy of reliable algorithms with newly developed hardware. The reliability
is proven by the experience in the field of almost 1,000,000 SIPROTEC devices.
The relay provides numerous functions to respond flexibly to the system requirements
and to deploy the invested capital economically. Examples for this are: exchangeable interfaces, flexible protection
functions and the integrated automation level (CFC).


Highlights
• Removable current and voltage terminal blocks
• Binary input thresholds settable using DIGSI (3 stages)
• Current taps (1A/5A) settable using DIGSI
• 9 programmable function keys
• 6-line display
• Buffer battery exchangeable from the front
• USB front port
• 2 additional communication ports
• IEC 61850 with integrated redundancy (electrical or optical)
• Relay-to-relay communication through Ethernet with IEC 61850 GOOSE
• Millisecond-accurate time synchronization through Ethernet with SNTP

Protection functions
• Time-overcurrent protection (50, 50N, 51, 51N)
• Directional overcurrent protection, ground (67N)
• Sensitive dir./non-dir. ground-fault detection (50Ns, 67Ns)
• Displacement voltage (64)
• Inrush restraint
• Motor protection
– Undercurrent monitoring (37)
– Starting time supervision (48)
– Restart inhibit (66/86)
– Locked rotor (14)
– Load jam protection (51M)
• Overload protection (49)
• Temperature monitoring
• Under-/overvoltage protection (27/59)
• Under-/overfrequency protection (81O/U)
• Breaker failure protection (50BF)
• Phase unbalance or negative-sequence protection (46)
• Phase-sequence monitoring (47)
• Lockout (86)

Control functions/programmable logic
• Commands for the ctrl. of CB, disconnect switches (isolators/isolating switches)
• Control through keyboard, binary inputs, DIGSI 4 or SCADA system
• User-defined logic with CFC (e.g. interl.)